Partners |
|
Customer |
|
|
Support Online |
|
Sales 01 |
Mr.Binh |
One card solution
|
|
|
|
|
|
|
Total access |
 |
|
|
|
|
Access Control System |
|
|
 |
|
|
SK-ACP |
The SK-ACP Advanced Control Panel is a highly sophisticated, yet simple to use, two door access control unit. The unit accepts readers that have a Wiegand output with almost any card technology, including Proximity, Touch Card, Wiegand, Magnetic Stripe, Bar Code, Optical, and Biometric. Each of the two doors controlled by the unit is completely independent of the other and is configured, programmed and viewed separately. Each has a separate node address.
|
Each of the two doors controlled by the SK-ACP has two programmable inputs which may be programmed to function as a door open, remote inactive, door monitor, tamper, arming circuit, door unlock, or user defined input. Each of the two doors controlled by the SK-ACP has two outputs. One output is the relay that activates the door operating device. The other output is programmable to activate under one of many possible alarm conditions, time zone or card violations.
As a stand alone, the unit may be programmed using a PC either locally or via a modem over standard phone lines. Transaction information is stored by the unit and may be downloaded to a PC or printer.
Over 100 SK-ACP units may be connected together to control over 200 passageways with SK-NETTM software, using a single twisted pair RS-485 bus. SK-NETTM software allows integration of the units into a full featured Window® based, access control system.
Specification
- Supports Two Wiegand Output Card Readers
- 65,000 Card Capacity
- 4,800 Date and Time Stamped Stored Events
- 15 Programmable Time Zones with Weekly Schedule Plus Holidays
- 32 Programmable Holidays
- Over 100 panels can be linked to a PC with SK-NETTM software using a simple RS-485 bus
- Modem Capability for Remote Locations*
- TCP/IP Capability for LAN Connection*
* Requires additional equipment
Connection Diagram

PHYSICAL |
|
SK-ACP-LE |
SK-ACP-SE |
SK-ACP-NE
(ALSO AVAILABLE)
|
|
Depth
|
3.00" (7.62 cm)
|
2.5" (6.35 cm)
|
1.0" (2.54 cm)
|
|
Width
|
10.0" (25.40 cm)
|
8.0" (20.32 cm)
|
4.8" (12.19 cm)
|
|
Height
|
11.0" (27.94 cm)
|
8.0" (20.32 cm)
|
4.6" (11.68 cm)
|
|
Weight
|
68.8 oz (1.95 kg)
|
36 oz. (1.02 kg)
|
N/A
|
|
Material
|
All Steel
|
All Steel
|
N/A
|
|
Color
|
Beige
|
Beige
|
N/A
|
|
|
16.5-24 VAC, 20 VA or 16-30 VDC, 100 mA plus reader current draw
|
|
* A 12 VDC Power Supply may be used if connected to Battery Back-UP Leads.
100mA, plus 150 mA max. reader current draw per reader (Power Supply not included).
|
|
|
|
BACK-UP BATTERY |
|
12 V, 1.2 - 6 Ah (Optional, not included)
|
|
|
SOFTWARE |
|
|
|
SK-NETTM Software Version 2.0 or greater
|
|
|
CARD READERS |
|
|
Connect two card readers with two-line Wiegand output, up to 40 bits.
Provides 14 VDC, 150 mA max. power for each card reader. |
|
OUTPUTS |
2 Per Door (Total of 4) |
Latch & Alarm Shunt |
DPDT contact, 2A, up to 220 VAC or 30 VDC |
|
Auxiliary |
DPDT contact, 2A, up to 220 VAC or 30 VDC
|
|
INPUTS |
2 Per Door (Total of 4) |
Auxiliary 1 |
Requires SPST contact closure
|
|
Auxiliary 2 |
Requires SPST contact closure |
|
COMMUNICATION |
|
RS-232 |
5-Wire Shielded Cable, up to 38.4K baud, full duplex, (8N1) - UP TO 100' |
|
RS-485 |
Single Twisted Pair, shielded cable with a signal ground- UP TO 4000'
|
|
Wiegand Input (2) |
Programmable up to 40 bits14 VDC @ 150 mA supplied to each reader,
|
|
Modem |
Requires Hayes compatible - 1.2 to 38.4k baud |
|
LAN |
Requires external device server |
|
Printer |
Serial Printer (or Parallel printer with serial converter) |
|
ENVIRONMENT |
Access Control Unit and Card/Key Tag |
|
Ambient Temperature |
-40° to +70°C (-40° to +158°F) |
|
Humidity |
0% to 95% Relative Humidity (non-condensing) |
|
OPERATIONAL |
Per Door <
|
Card Capacity |
65,535 /Door (Highest card number = 65,535) |
Time Zones |
15 for card access, one door unlock; full week plus holiday in one-half hour segments; 32 programmable holidays; selectable automatic daylight saving time. |
Facility Code |
Up to 16 different codes simultaneously |
Latch/Alarm Shunt Timer |
Programmable from 1/4 to 30 seconds |
Antipassback |
Real or Timed (1 to 30 minutes); hard or soft |
Auxiliary Inputs (2) |
Programmable for door monitor, tamper monitor, remote |
Auxiliary Output (1) |
Output is programmable to activate under one of many |
|
Limited Use Cards |
4,000 (in a block within 65,535) programmable from 1-500 |
|
Transaction Storage |
4,864 events
|
|
Memory |
Non-volatile
|
|
This product complies with UL 294 Standards, CE (European Standards), and with Part 15 of the Class B FCC Rules.
|
|
|
|
|
|
|
|